Journal Information
Vol. 34. Issue 3.
Pages 213.e1-213.e3 (March 2015)
Share
Share
Download PDF
More article options
Visits
4719
Vol. 34. Issue 3.
Pages 213.e1-213.e3 (March 2015)
Case report
Open Access
Sealing a ruptured non-culprit coronary plaque in a patient with acute myocardial infarction with bioresorbable vascular scaffolds
Selar com suportes vasculares bioabsorvíveis a rotura de uma placa coronária não culpada num doente com enfarte agudo do miocárdio
Visits
4719
Javier Cuesta, Fernando Rivero, Teresa Bastante, Amparo Benedicto, Guillermo Diego, Fernando Alfonso
Corresponding author
javicuestacuesta@hotmail.com

Corresponding author.
Hospital Universitario de La Princesa, Madrid, Spain
This item has received

Under a Creative Commons license
Article information
Abstract
Full Text
Bibliography
Download PDF
Statistics
Figures (2)
Abstract

A 49-year-old man was admitted to the emergency department suffering from a large anterior myocardial infarction that was treated by rescue PCI. The patient also had a moderate but complex lesion in the proximal segment of the right coronary artery. Optical coherence tomography showed striking images of a ruptured and ulcerated plaque with significant thrombus content. Although the lumen was not compromised, these unique findings prompted us to treat this non-culprit lesion. We selected a bioresorbable vascular scaffold with the aim of sealing and passivating this complicated and high-risk plaque.

Keywords:
Optical coherence tomography
Non-culprit lesion
Bioresorbable vascular scaffolds
Resumo

Homem de 49 anos, admitido no serviço de urgência, que padecia de enfarte do miocárdio anterior extenso e que tinha sido tratado com intervenção coronária percutânea (ICP) de recurso. O doente também apresentou lesão moderada mas complexa no segmento mais próximo da coronária direita. A tomografia de coerência óptica revelou imagens impressionantes de uma placa com rotura e ulcerada com trombos significativos. Embora o lúmen não tenha sido comprometido, estas constatações únicas levaram-nos a tratar rapidamente esta lesão não culpada. Selecionámos um suporte vascular bioabsorbível com o objetivo de selar e de solucionar o caso desta placa complicada e de alto risco.

Palavras-chave:
Tomografia de coerência ótica
Lesão não culpada
Suportes vasculares bioabsorbíveis
Full Text
Case report

A 49-year-old man, a smoker and with hypertension and dyslipidemia, was admitted to the emergency department for rescue primary angioplasty. Marked anterior ST-segment elevation (5 mm in leads V2-V4) was seen on the ECG. Coronary angiography showed a critical coronary lesion in the mid segment of the left anterior descending coronary artery in which a 2.75 mm×13 mm bare-metal stent was successfully implanted. The right coronary artery showed a complex but moderate lesion in its proximal segment.

Two days later, a new coronary angiogram was performed to further assess the proximal right coronary lesion. Optical coherence tomography (OCT) disclosed a large thin-cap fibroatheroma with a clear fibrous-cap rupture and a large cavity along the direction of coronary flow (Figure 1). Several coronary thrombi were also detected. Although the lumen area was relatively preserved, these unique OCT findings of active plaque complication were instrumental in the decision to treat this lesion. A bioresorbable vascular scaffold (BVS) was successfully implanted (Figure 2).

Figure 1.

Optical coherence tomography. (A) A ruptured cap and a large posterior cavity (+) are visualized; (B and C) images showing a lipid plaque (L) and a large red thrombus (T) protruding into the coronary lumen (arrows); (D) longitudinal reconstruction highlighting the ruptured plaque cavity (+) in the flow direction. GC: guiding catheter; *: wire artefact.

(0.6MB).
Figure 2.

Optical coherence tomography images after intervention. (A) A large residual thin-cap fibroatheroma is partially visualized behind the scaffold; (B and C) a residual thrombus (arrows) protruding slightly into the lumen and a lipid plaque (L) are also visualized; (D) longitudinal image showing a fully expanded scaffold. GC: guiding catheter; *: wire artefact.

(0.69MB).
Discussion

Multivessel coronary artery disease is present in nearly half of patients with acute myocardial infarction undergoing primary angioplasty.1 The optimal timing for the treatment of non-culprit lesions in these patients remains controversial, although a staged procedure is frequently selected following current recommendations.2 Only severe coronary lesions are treated during these repeat procedures. However, intracoronary imaging techniques have demonstrated that many patients with acute myocardial infarction also have complicated plaques in non-culprit lesions. Notably, some of these complicated plaques are not identified by angiography. OCT provides novel insights in this regard as its unique resolution enables the presence of plaque rupture with associated intracoronary thrombus to be readily identified.3 In our patient, angiography showed a complex but moderate lesion in the proximal right coronary artery, but OCT disclosed the presence of a large complicated thin-cap fibroatheroma with a large rupture associated with intracoronary thrombi. We used a BVS to treat this complicated plaque, in spite of a relatively large residual minimal lumen area, with excellent results. BVS are especially attractive to seal and passivate vulnerable coronary plaques, as these devices may lead to complete vessel wall restoration at late follow-up.4 Although there is little evidence to support this strategy, further studies are warranted to answer this important clinical question. Whether the additional information provided by OCT can help guide interventions in non-culprit lesions in patients presenting with an acute myocardial infarction deserves a prospective evaluation.

Ethical disclosuresProtection of human and animal subjects

The authors declare that the procedures followed were in accordance with the regulations of the relevant clinical research ethics committee and with those of the Code of Ethics of the World Medical Association (Declaration of Helsinki).

Confidentiality of data

The authors declare that they have followed the protocols of their work center on the publication of patient data.

Right to privacy and informed consent

The authors declare that no patient data appear in this article.

Conflicts of interest

The authors have no conflicts of interest to declare.

References
[1]
F. Alfonso.
Multivessel intervention during primary angioplasty: too greedy?.
JACC Cardiovasc Interv, 3 (2010), pp. 32-34
[2]
P.J. Vlaar, K.D. Mahmoud, D.R. Holmes, et al.
Culprit vessel only versus multivessel and staged percutaneous coronary intervention for multivessel disease in patients presenting with ST-segment elevation myocardial infarction: a pairwise and network meta-analysis.
J Am Coll Cardiol, 58 (2011), pp. 692-703
[3]
Y. Ino, T. Kubo, A. Tanaka, et al.
Difference of culprit lesion morphologies between ST-segment elevation myocardial infarction and non-ST-segment elevation acute coronary syndrome: an optical coherence tomography study.
JACC Cardiovasc Interv, 4 (2011), pp. 76-82
[4]
J.A. Ormiston, P.W. Serruys, Y. Onuma, et al.
First serial assessment at 6 months and 2 years of the second generation of absorb everolimus-eluting bioresorbable vascular scaffold: a multi-imaging modality study.
Circ Cardiovasc Interv, 5 (2012), pp. 620-632
Copyright © 2014. Sociedade Portuguesa de Cardiologia
Idiomas
Revista Portuguesa de Cardiologia (English edition)
Article options
Tools
en pt

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

By checking that you are a health professional, you are stating that you are aware and accept that the Portuguese Journal of Cardiology (RPC) is the Data Controller that processes the personal information of users of its website, with its registered office at Campo Grande, n.º 28, 13.º, 1700-093 Lisbon, telephone 217 970 685 and 217 817 630, fax 217 931 095, and email revista@spc.pt. I declare for all purposes that the information provided herein is accurate and correct.