Sudden cardiac death (SCD) remains a major cause of mortality, and risk stratification based on left ventricular ejection fraction (LVEF) has significant limitations. Artificial intelligence (AI) has emerged as a potential approach for modeling complex arrhythmic risk. We conducted a systematic review with prespecified anchor subgroup reporting (without pooling) to evaluate the performance of AI models in predicting SCD and malignant ventricular arrhythmias. We searched MEDLINE/PubMed, Embase, and Scopus from inception to 3 October 2025. Anchor subgroup reporting was restricted to studies reporting area under the receiver-operating characteristic curve (AUROC) with 95% confidence intervals (CIs) within predefined modality/horizon subgroups. Studies without CIs or relying on cross-validation variance were summarized narratively as supplementary evidence. Thirteen studies met the inclusion criteria; five reported AUROC with 95% CIs within prespecified modality/horizon subgroups and were included as anchor subgroup estimates (k=1 per subgroup). Methodological quality and reporting were limited: 54% of studies (7/13) were classified as high risk of bias according to PROBAST+AI, driven by cross-validation-only designs, unit-of-analysis issues, limited external validation, and sparse calibration reporting. Among anchor estimates, deep learning on single-lead ambulatory ECG showed high discrimination for near-term ventricular tachyarrhythmias (AUROC 0.948, 95% CI 0.926–0.967), while 12-lead ECG models achieved good performance for long-term SCD (AUROC 0.820, 95% CI 0.794–0.847). The multimodal anchor estimate (AUROC 0.84) was numerically higher than the CMR radiomics anchor (AUROC 0.70), but this represents an indirect between-study contrast. AI-ECG models show high reported discrimination in near-term risk windows, but cross-study comparisons are indirect, and methodological heterogeneity remains a barrier to translation into clinical practice.
A morte súbita cardíaca (MSC) permanece uma causa importante de mortalidade, e a estratificação de risco com base na fração de ejeção ventricular esquerda (FEVE) apresenta limitações significativas. A inteligência artificial (IA) tem emergido como uma possível abordagem para a modelação do risco arrítmico complexo. Realizámos uma revisão sistemática com apresentação pré-especificada de subgrupos de referência (sem meta-análise), para avaliar o desempenho de modelos de IA na predição de MSC e de arritmias ventriculares malignas, com apreciação do risco de viés segundo o PROBAST+AI. Pesquisámos nas bases de dados MEDLINE/PubMed, Embase e Scopus desde o início até ao dia 3 de outubro de 2025. A apresentação de subgrupos de referência foi limitada a estudos que reportaram a área sob a curva ROC (AUROC) com intervalos de confiança (IC) de 95% em subgrupos pré-definidos por modalidade e horizonte temporal; estudos sem IC, ou baseados apenas na variação de validação cruzada, foram sintetizados narrativamente como evidência suplementar. Treze estudos cumpriram os critérios de inclusão; cinco forneceram AUROC com IC de 95% nos subgrupos pré-especificados e foram incluídos como estimativas de referência (k=1 por subgrupo). A qualidade metodológica e o relato foram globalmente limitados: 54% dos estudos (7/13) foram classificados como alto risco de viés pelo PROBAST+AI, sobretudo devido a desenhos exclusivamente com validação cruzada, problemas de unidade de análise, validação externa limitada e reporte escasso de calibração. Entre as estimativas de referência, os modelos de deep learning aplicados a ECG ambulatório de derivação única demonstraram elevada discriminação para taquiarritmias ventriculares em horizonte de curto prazo (AUROC 0,948; IC 95% 0,926–0,967), enquanto modelos baseados em ECG de 12 derivações apresentaram bom desempenho para MSC de longo prazo (AUROC 0,820; IC 95% 0,794–0,847). A estimativa de referência multimodal (AUROC 0,84) foi numericamente superior à estimativa de referência radiómica da ressonância magnética cardíaca (AUROC 0,70), embora se trate de uma comparação indireta entre estudos. Os modelos de IA aplicados ao ECG apresentam elevada discriminação relatada em janelas de risco de curto prazo; contudo, as comparações entre estudos permanecem indiretas e a heterogeneidade metodológica continua a constituir uma barreira para a aplicação clínica.
Sudden cardiac death (SCD), defined as an unexpected death from cardiac causes occurring within one hour of symptom onset or within 24 hours of being observed alive, remains a major public health challenge. SCD accounts for a substantial proportion of cardiovascular mortality.1–3 Although less common, cardiac arrest also occurs in pediatric populations with distinct epidemiology.4 Across Europe and North America, incidence rates range from 30 to 45 per 100000 person-years, varying by age, gender, and comorbid risk factors.2,3 In adults, coronary artery disease accounts for approximately 70–75% of cases, while cardiomyopathies, channelopathies, structural or infiltrative heart disease, and idiopathic substrates comprise much of the remainder.2,3 SCD can also manifest in individuals with no evident high-risk features, underscoring the therapeutic importance of earlier and more accurate risk stratification.
Current guideline-based strategies rely heavily on left ventricular ejection fraction (LVEF) thresholds (typically ≤35%) to select candidates for prophylactic implantable cardioverter-defibrillator (ICD) therapy.5 The 2022 European Society of Cardiology (ESC) Guidelines acknowledge that reduced LVEF is a cornerstone but an imperfect discriminator: SCD can occur with preserved LVEF, and many patients below the threshold never experience arrhythmic events.5 The guidelines also incorporate additional tools (e.g., CMR, genetic testing, electroanatomic mapping) to refine risk in select populations.5 Nonetheless, they note that the integration of multimodal predictors remains methodologically inconsistent and that risk stratification is “suboptimal” in several clinical contexts.5 Prior ESC guidelines and expert commentary provide additional context.6–8
Beyond LVEF, risk stratification in selected populations increasingly incorporates disease-specific markers, advanced imaging, genetic testing, ambulatory rhythm monitoring, and device-derived arrhythmic burden. Implantable loop recorders may also provide clinically relevant arrhythmia detection in selected cardiomyopathy populations and may influence downstream management decisions, including consideration of device therapy.9 However, these approaches remain population-specific and do not eliminate the need for generalizable, externally validated, and clinically calibrated risk-prediction models.
This approach excludes a significant number of at-risk individuals from existing primary-prevention criteria and subjects certain treated patients to device-related risks without encountering arrhythmic events.10,11 Conversely, many patients who receive an ICD based on a low LVEF never experience a life-saving shock, exposing them to device-related complications without benefit. This diagnostic gap underscores the urgent need for more sophisticated, multidimensional risk markers that move beyond a single hemodynamic metric. Adjunctive risk markers – including LGE on CMR, myocardial strain, T-wave alternans, non-sustained ventricular tachycardia, and genetic risk scores – have been investigated, yet each adds only modest incremental value and performs inconsistently across broader populations.5,12
In this context, artificial intelligence (AI) and machine learning (ML) have been proposed as instruments for advanced risk stratification. By modeling high-dimensional and heterogeneous data and capturing nonlinear interactions, these methods may complement conventional approaches and improve discrimination in selected settings. Early studies applying AI to 12-lead ECG, ambulatory ECG, intracardiac electrograms, and imaging data have demonstrated encouraging discrimination for arrhythmic outcomes.13–15 Deep learning models trained on raw ECG signals, for example, have reported good discrimination across tasks and horizons, with AUROC ranging from 0.70 to 0.95 depending on the endpoint and prediction window.13–16 In other work, single-lead ambulatory ECG AI has predicted near-term ventricular arrhythmias with high accuracy.16 Multimodal AI frameworks integrating imaging, ECG, and clinical variables have reported incremental gains over unimodal predictors.13,14 Nonetheless, heterogeneity in design, outcomes, prediction time frames, validation methodologies, and inadequate reporting of calibration and uncertainty (e.g., confidence intervals) currently constrains clinical application. Moreover, even the most advanced AI models have yet to enter formal guideline recommendations. Consistent with this, the 2022 ESC Guidelines do not currently endorse any AI-based risk tool for routine clinical use.5 This gap highlights the need for a systematic, methodologically rigorous appraisal of the emerging evidence. Previous narrative and systematic reviews have summarized early applications of AI for SCD risk prediction; a few studies have compared performance across ECG, imaging, and device-based models while formally assessing risk of bias with contemporary tools such as PROBAST+AI (Prediction model Risk Of Bias Assessment Tool for Artificial Intelligence).17
Despite rapid growth in AI applications for SCD prediction, clinical uptake remains limited by heterogeneous endpoints, variable validation designs, and incomplete reporting. Consequently, we conducted a PRISMA-guided systematic review to compare reported performance across modalities and time horizons, while assessing methodological quality with PROBAST+AI.17
MethodsProtocol registration and reporting standardsThe protocol was defined a priori and registered in PROSPERO (CRD420251163095); the full protocol is provided in the Supplementary Materials. This systematic review was conducted in accordance with PRISMA 2020.18 We prespecified anchor estimates – one AUROC (95% CI) per modality/horizon subgroup (k=1) – reported at the study level without pooling. Risk of bias and applicability were assessed using PROBAST+AI,17 an adaptation of PROBAST for AI/machine-learning prediction models.
Eligibility criteriaEligible studies were original peer-reviewed articles that developed or validated an AI/ML prediction model for SCD-related arrhythmic outcomes (SCD, sustained VT/VF, or appropriate ICD therapy) using clinical data and/or electrocardiographic (12-lead or ambulatory/Holter), device-derived (ICD/IEGM), or imaging data (e.g., CMR). Studies addressing adjacent prediction tasks (e.g., IHCA prediction, rhythm phenotyping, prehospital triage) were retained as supplementary evidence and analyzed separately from the prespecified anchor subgroups. Studies had to report model discrimination as AUROC or a C-statistic. Studies without a reported discrimination metric (AUROC/C-statistic) were excluded. For inclusion in anchor subgroup reporting, studies additionally had to report AUROC with a 95% confidence interval; studies without CIs were included in qualitative synthesis only.
Information sources and search strategyComplete, database-specific search strings for MEDLINE/PubMed, Embase, and Scopus (including field tags and limits) are provided in the Supplementary Methods (PRISMA-S). We searched MEDLINE/PubMed, Embase, and Scopus from inception to 3 October 2025; searches were executed on 3 October 2025 with no date restrictions. We avoided restrictive AI/ML filters because indexing is inconsistent and instead combined broad AI/ML terms with arrhythmic outcome terms. We additionally performed backward citation chasing of included studies and relevant reviews; no further eligible peer-reviewed prediction model studies were identified. An example strategy adapted to each database was:
> (“sudden cardiac death” OR “ventricular arrhythmia” OR “cardiac arrest” OR “ICD therapy”) AND (“artificial intelligence” OR “machine learning” OR “deep learning”).
> Reference lists of included studies and relevant reviews were hand-searched to identify additional publications.
Study selectionRecords were imported into Zotero and deduplicated using the DOI and title matching followed by manual verification. Given the small yield (n=15), we used an intentionally inclusive title/abstract screen and assessed all potentially relevant records in full text. Fifteen full texts were assessed for eligibility; two were excluded (one diagnostic application rather than prediction, and one overlapping dataset without unique outcomes), leaving 13 included studies for qualitative synthesis. Five studies additionally reported AUROC with 95% CIs within prespecified modality/horizon subgroups and contributed to the anchor subgroup reporting.
Data extractionTwo reviewers independently screened titles/abstracts and full texts. Disagreements were resolved through discussion, re-checking of the source article, and consensus between the two reviewers. No third-reviewer adjudication was required. Two independent reviewers extracted study design, population and sample size, endpoint definition (SCD, VT/VF, ICD therapy, IHCA), prediction horizon (seconds or minutes, ≤30 days, 1 year, multi-year), data modality, AI/ML model type (e.g., convolutional neural network, random forest, logistic regression), validation level (external vs internal/cross-validation), discrimination metrics (AUROC with 95% CI where reported), operating characteristics (sensitivity, specificity, positive and negative predictive values), and calibration measures. Independent external validation was defined as evaluation in a cohort, institution, registry, or dataset not used for model training, tuning, feature selection, or internal testing. Split-sample testing, cross-validation, temporal/internal validation, and proof-of-concept testing within the same source dataset were not classified as independent external validation. For studies with multiple models or horizons, we prioritized externally validated estimates when available; otherwise, we selected the model most aligned with the subgroup definition to ensure that each study contributed one estimate per subgroup. Data extraction was limited to peer-reviewed published results to ensure the use of verified final model performances. Studies lacking a 95% AUROC CI were excluded from the anchor subgroup reporting but are presented narratively and graphically.
Outcomes and subgroup definitionsOutcomes and prediction horizons were prespecified, distinguishing SCD from appropriate ICD therapy and near-term from short- and long-term risk windows. The primary outcome was discrimination (AUROC) of AI/ML models for predicting arrhythmic events. To account for heterogeneity in outcome definitions and horizons, anchor subgroup reporting was prespecified for five subgroups:
- 1.
Holter/ambulatory ECG (near-term sustained VT/VF)
- 2.
ICD/IEGM (short/near-term VT/VF/ICD therapy)
- 3.
12-lead ECG (long-term SCD)
- 4.
CMR radiomics (long-term VA/ICD)
- 5.
Multimodal (intermediate-term VA/ICD)
Studies predicting in-hospital cardiac arrest (IHCA), time-dependent C-statistics without a single AUROC, or event phenotyping (e.g., PEA vs VF) were included in the review but excluded from anchor subgroup reporting.
Risk of bias and applicabilityAll studies were appraised using PROBAST+AI17 across the four domains: population, predictors, outcome, and analysis. PROBAST+AI was applied as published, without modification of its original domains or signaling-question structure. Two reviewers independently performed the PROBAST+AI assessment. Disagreements were resolved through discussion, re-checking of the source article, and consensus between the two reviewers. No third-reviewer adjudication was required. Key considerations included potential data leakage, sample size, and number of events per predictor, handling of missing data, internal vs external validation, and reporting of calibration. Overall risk of bias was rated as low, high, or unclear following PROBAST+AI guidance. Overall risk of bias was assessed according to PROBAST+AI guidelines: an overall judgment of ‘high’ was assigned if any domain was rated high; ‘unclear’ was reserved for insufficient reporting without clear high-risk features. Applicability concerns were assessed in parallel and are reported alongside risk-of-bias judgments in the Supplement.
Statistical analysisGiven substantial clinical and methodological heterogeneity across studies (endpoints, case-mix, and prediction horizons), we did not perform a pooled meta-analysis. Pooling would imply exchangeability of effects across materially different outcomes and horizons, which was not met. We therefore prespecified anchor subgroup reporting by modality/horizon, presenting one rule-based anchor AUROC estimate with 95% CI per subgroup (k=1 each) without pooling; heterogeneity statistics (Q, I2, τ2) and prediction intervals were not calculated.19,20 Anchor studies were defined as those reporting AUROC with 95% CIs within the prespecified subgroups; external validation was prioritized where available, but was not required when no externally validated study existed for a subgroup. Studies without AUROC CIs or relying on cross-validation variance were summarized as supplementary evidence. Analyses and visualizations were performed in Python 3.11 (pandas, matplotlib).
ResultsFifteen full texts were assessed for eligibility; two studies were excluded (one non-predictive/diagnostic application and one overlapping dataset without unique outcomes), leaving 13 included studies. Five studies contributed to the prespecified anchor estimates (AUROC with 95% CI within modality/horizon subgroups), whereas the remaining studies were synthesized narratively due to non-matching endpoints/horizons or reporting/design constraints. The study selection process is summarized in the PRISMA flow diagram (Figure 1).
PRISMA 2020 flow diagram. After deduplication, 15 records remained for screening. Fifteen records were screened, and 15 full texts were assessed. Two studies were excluded (one diagnostic application; one overlapping dataset), leaving 13 included studies. Five studies reported AUROC with 95% CI and contributed to the prespecified anchor estimates. Abbreviation: PRISMA: Preferred Reporting Items for Systematic Reviews and Meta-Analyses.
Included studies varied in design, data modality, prediction horizon, and outcome definitions. Cohorts ranged from selected device populations to case–control studies and multicenter registries. ECG was the most common input modality (single-lead ambulatory recordings, device electrograms, or 12-lead ECG), whereas CMR and multimodal approaches were less frequent. Endpoints included sudden cardiac death, sustained ventricular tachycardia/ventricular fibrillation, appropriate ICD therapies, and in-hospital cardiac arrest. Key study characteristics are summarized in Table 1.
Characteristics of included studies.
| Study | Population/endpoint | Sample/setting | Model type | Validation | Performance |
|---|---|---|---|---|---|
| Fiorina 202516 | 14-Day single-lead ambulatory ECG recordings | n=183177 (VT-positive 804), internal validation n=43580 (VT-positive 197), external test n=20497 (VT-positive 103); multicountry (6 countries) | CNN/DL | Internal+external validation | AUROC internal 0.957 (0.943–0.971), external 0.948 (0.926–0.967) |
| Cha 202421 | ICD/IEGM, impending VT/VF (seconds) | n=13516 ICD patients; 301647 IEGM recordings | DNN | Internal | AUROC 0.83 (0.79–0.87) |
| Holmstrom 2024 (Commun Med)14 | 12-Lead ECG, long-term SCD | Case–control; 1796 cases/1342 controls; external 714/714 | CNN | External | AUROC 0.820 (0.794–0.847) |
| Amyar 202522 | CMR radiomics (DCM) | n=383 (270 deriv./113 ext.) | Radiomics+LR | External | AUROC 0.70 (0.59–0.85) |
| Kolk 2024 (Sci Rep)13 | Multimodal DEEP-RISK | n=289 NICM; two hospitals | Multimodal DL | External | AUROC 0.84 (0.71–0.96) |
| Oberdier 202523 | 12-Lead ECG, SCA <1d | 7015 subjects (605 SCA, 6410 controls); train/test split (test set 221 SCA, 1046 controls) | CNN | Internal split/CV | AUROC 0.77 (no CI) |
| Ginder 202324 | ICD remote monitoring, 30d ICD therapy | IMPACT trial: 2718 total; 2413 analyzed; 59807 transmissions (unit-of-analysis issue) | NN vs LR | Internal | NN AUROC 0.90 (no CI) |
| Gendelman 202425 | Holter HRV/morphology, VT patient | n=1773 | ML (various) | Internal (CV) | AUROC 0.76±0.07 (CV folds) |
| Kwon 202015 | 12-Lead ECG, IHCA (24 h) | 47505 ECGs/25672 patients; external test 10728 ECGs (10728 patients) | Deep learning (ECG-AI) | External | AUROC 0.948 (0.930–0.966) external |
| Telangore 202426 | ECG proof-of-concept, early SCA | Small public datasets | CNN | Internal (POC) | AUROC >0.90 (no CI) |
| Kolk 2024 (eBioMedicine)27 | Dynamic ECG ICD cohort, time-dependent | n=2942 ICD patients; 32129 ECG recordings | ML (time-dependent) | Internal | Time-dependent AUROC (reported as curves; mean AUROC 0.738±0.07) |
| Holmstrom 2024 (Circ Arrhythm Electrophysiol)29 | Index SCA rhythm (PEA vs VF) | Internal cohort n=421; external cohort n=220 (EMS-witnessed SCA) | XGBoost (gradient boosting) | External | AUROC 0.717 (0.591–0.843) [internal 0.684 (0.610–0.758)] |
| Rahadian 202428 | OHCA refractory VF/VT triage | n=20713; derivation 17162; validation 3551 (prehospital OHCA cohort) | LR, LASSO, RF | Internal | AUROC 0.738 (0.701–0.774) |
Summary of all included studies, detailing population and endpoint definition, sample size and setting, model type, validation strategy (internal vs external, including cross-validation where applicable), and reported discrimination (AUROC or time-dependent C-statistic).
In the validation column, “Internal split/CV” indicates testing within the same source dataset using split-sample testing and/or cross-validation, without a clearly independent external validation cohort.
Abbreviations: AUROC: area under the receiver-operating characteristic curve; CMR: cardiac magnetic resonance; CNN: convolutional neural network; CV: cross-validation; DCM: dilated cardiomyopathy; DL: deep learning; DNN: deep neural network; ECG: electrocardiogram; ext.: external; HRV: heart rate variability; ICD: implantable cardioverter-defibrillator; IEGM: intracardiac electrogram; IHCA: in-hospital cardiac arrest; LASSO: least absolute shrinkage and selection operator; LR: logistic regression; ML: machine-learning; NICM: non-ischemic cardiomyopathy; OHCA: out-of-hospital cardiac arrest; POC: proof-of-concept; pts: patients; RF: random forest; SCA: sudden cardiac arrest; SCD: sudden cardiac death; VT: ventricular tachycardia; VF: ventricular fibrillation.
Using a strict definition of validation in an independent external cohort, independent external validation was reported in six of 13 included studies (46.2%). The remaining seven studies (53.8%) relied on internal validation, cross-validation, split-sample testing, proof-of-concept validation, or validation strategies without a clearly independent external cohort.
Risk of bias assessment using PROBAST+AI17 rated six of 13 studies (46.2%) as having an overall low risk and 7 of 13 studies (53.8%) as high risk (Table 2; Supplementary Table S2). Main concerns were limited sample sizes and event counts relative to model complexity, reliance on internal cross-validation without independent external cohorts, unit-of-analysis issues (e.g., repeated transmissions), and incomplete reporting of calibration or confidence intervals.
PROBAST+AI risk of bias assessment.17
| Study | Population | Predictors | Outcome | Analysis | Overall risk of bias |
|---|---|---|---|---|---|
| Fiorina 202516 | Low | Low | Low | Low | Low |
| Cha 202421 | Low | Low | Low | High | High |
| Holmstrom 2024 (Commun Med)14 | Low | Low | Low | Low | Low |
| Amyar 202522 | Low | Low | Low | Low | Low |
| Kolk 2024 (Sci Rep)13 | Low | Low | Low | Low | Low |
| Oberdier 202523 | Low | Low | Low | High | High |
| Ginder 202324 | Low | Low | Low | High | High |
| Gendelman 202425 | Low | Low | Low | High | High |
| Kwon 202015 | Low | Low | Low | Low | Low |
| Telangore 202426 | High | Low | Low | High | High |
| Kolk 2024 (eBioMedicine)27 | Low | Low | Low | High | High |
| Holmstrom 2024 (Circ Arrhythm Electrophysiol)29 | Low | Low | Low | Low | Low |
| Rahadian 202428 | Low | Low | Low | High | High |
Domain-level and overall risk of bias judgments for each included study according to the PROBAST+AI framework, across Participants (Population), Predictors, Outcome, and Analysis domains. Each domain, as well as the overall rating, is classified as low or high risk of bias.
Across prespecified subgroups, evidence was sparse (k=1 each); therefore, estimates are presented at the study level (no pooling).
In a large multi-country dataset of 14-day single-lead ambulatory ECG recordings (external test n=20497), Fiorina reported an AUROC of 0.948 (95% CI 0.926–0.967).16 Short-term forecasting of ventricular tachyarrhythmias from intracardiac electrograms was reported in Cha, with an AUROC of 0.83 (95% CI 0.79–0.87),21 although sensitivity was highly dependent on the tolerated false-positive rate. Long-term SCD prediction from 12-lead ECG yielded an AUROC of 0.820 (95% CI 0.794–0.847) in Holmstrom.14 In contrast, radiomics applied to CMR images in dilated cardiomyopathy achieved only modest discrimination (AUROC 0.70, 95% CI 0.59–0.85) in Amyar.22 Multimodal integration of CMR, ECG, and clinical data in the DEEP-RISK model (Kolk) achieved an AUROC 0.84 (95% CI 0.71–0.96).13 These anchor results by modality and prediction horizon are summarized in Table 3, with an expanded breakdown by subgroup provided in Supplementary Table S3. Because each subgroup included only one anchor study, no formal pooling was performed; instead, anchor AUROC estimates with 95% confidence intervals are reported as the prespecified benchmark per subgroup (Figure 2).
Anchor subgroup estimates.
| Subgroup | Anchor study | Performance (AUROC 95% CI) |
|---|---|---|
| Holter near-term | Fiorina 202516 | AUROC 0.948 (0.926–0.967) |
| ICD/IEGM short/near-term | Cha 202421 | AUROC 0.83 (0.79–0.87) |
| 12-Lead ECG long-term | Holmstrom 2024 (Commun Med)14 | AUROC 0.820 (0.794–0.847) |
| CMR radiomics long-term | Amyar 202522 | AUROC 0.70 (0.59–0.85) |
| Multimodal intermediate-term | Kolk 2024 (Sci Rep)13 | AUROC 0.84 (0.71–0.96) |
Summary of anchor AUROC estimates with 95% confidence intervals for key subgroups, stratified by data source (Holter, ICD/IEGM, 12-lead ECG, CMR radiomics, multimodal models) and prediction horizon (near-term ventricular arrhythmias, long-term sudden cardiac death, and multimodal intermediate-term risk).
Abbreviations: AUROC: area under the receiver-operating characteristic curve; CMR: cardiac magnetic resonance; ECG: electrocardiogram; ICD: implantable cardioverter-defibrillator; IEGM: intracardiac electrogram.
Anchor subgroup estimates (no pooling). Dot-and-whisker plot of AUROC (95% CI) for the five prespecified modality/horizon subgroups. Each subgroup is represented by a single anchor study (k=1), no pooled estimates are shown. Abbreviations: AUROC: area under the receiver operating characteristic curve; CMR: cardiac magnetic resonance; ICD/IEGM: implantable cardioverter-defibrillator intracardiac electrogram.
Supplementary evidence from studies without AUROC confidence intervals or relying on cross-validation variance aligned with the main pattern but remains exploratory given the reporting limitations. Oberdier23 reported an AUROC of 0.77 for SCA within 24 hours but without confidence intervals; Ginder24 described an AUROC of 0.90 for 30-day ICD therapy using device transmissions, though independence of observations was uncertain; and Gendelman25 reported an AUROC of 0.76 with fold-to-fold standard deviation but not an ROC-based CI. Other works, such as Telangore26 and Kolk,27 provided proof-of-concept or time-dependent C-statistics without single-point AUROC estimates. Overall, these studies suggest a similar direction, but cross-modality comparisons remain indirect and should be interpreted cautiously, given incomplete uncertainty reporting and design limitations. An evidence map of modalities and prediction horizons is presented in Figure 3, highlighting gaps where AUROC estimates with 95% CIs and independent external validation are unavailable.
Evidence map by modality and horizon. Visual summary of reported discrimination across included studies, highlighting anchor estimates (AUROC with 95% CI) versus supplementary evidence without CIs or with methodological constraints. Abbreviations: AUROC: area under the receiver operating characteristic curve; CMR: cardiac magnetic resonance; ICD/IEGM: implantable cardioverter-defibrillator intracardiac electrogram.
When analyzed by AI model family, convolutional and recurrent neural networks applied to ECG signals tended to report the highest discrimination, particularly for near-term arrhythmia prediction (AUROC 0.948 in the near-term ambulatory ECG anchor study).16 These comparisons are descriptive and reflect between-study differences in endpoints, horizons, and validation design. For long-term SCD prediction, similar models reported an AUROC of around 0.82.14 Multimodal deep learning combining imaging, ECG, and clinical data achieved an AUROC of 0.84, whereas the radiomics anchor study reported an AUROC of 0.70. Classical machine-learning algorithms such as logistic regression, LASSO, and random forests showed moderate performance where reported (AUROC 0.73–0.76).25,28 Calibration was inconsistently reported and rarely quantified using standard metrics, limiting interpretability across studies.
Overall, across the included evidence, deep learning applied to ECG signals, particularly ambulatory recordings, shows the highest reported discrimination in near-term windows. However, cross-modality comparisons are indirect, and the evidence remains fragmented across endpoints, horizons, and validation strategies.
DiscussionThis systematic review with anchor subgroup reporting summarizes the current evidence on AI/ML models for SCD-related and malignant ventricular arrhythmia prediction using ECG, device-derived signals, CMR radiomics, and multimodal inputs.
Primary evidence (anchor studies)Restricting to studies reporting AUROC with 95% confidence intervals, five studies contributed to the anchor subgroup reporting, each representing a prespecified subgroup. Among the five prespecified anchor subgroup estimates, four of five studies (80.0%) were externally validated. The only internally validated anchor estimate was the ICD/IEGM short/near-term subgroup. These anchor studies provide the most interpretable estimates in the current evidence base, but each subgroup was informed by a single dataset (k=1), precluding meta-analysis and heterogeneity assessment. Within this framework, single-lead ambulatory ECG analyzed with deep learning reported an AUROC of 0.948 for near-term prediction of ventricular tachyarrhythmias.16 Deep learning applied to 12-lead ECG reported an AUROC of around 0.82 for long-term SCD prediction.14 Multimodal integration of CMR, ECG, and clinical features reported an AUROC of 0.84.13 CMR radiomics alone reported an AUROC of 0.70.22 ICD/IEGM-based prediction of impending arrhythmias reported an AUROC of 0.83 but was validated only internally, with sensitivity dependent on the decision threshold.21
Supplementary evidence (not eligible for anchor subgroup reporting)Several additional studies were analyzed individually because they were ineligible for anchor subgroup reporting. Oberdier23 reported an AUROC of 0.77 for SCA within 24 hours using 12-lead ECG, but no confidence intervals were available, preventing inclusion as an anchor estimate. Ginder24 described an AUROC of 0.90 for ICD therapy prediction using remote device transmissions, but the unit of analysis was daily transmissions rather than independent patients, raising concerns regarding variance estimation. Gendelman25 reported an AUROC of 0.76 with fold-to-fold standard deviation, reflecting cross-validation variability rather than true ROC-based confidence intervals. Other proof-of-concept studies demonstrated high apparent discrimination (AUROC >0.90), but without external validation or standardized outcomes.26 Together, these results were broadly consistent in direction, but cross-study comparisons remain indirect and should be interpreted cautiously given incomplete uncertainty reporting and design limitations. These studies are summarized in Supplementary Table S4.
Performance by artificial intelligence model familyAnalysis across model types provides additional insights. Convolutional and recurrent neural networks applied directly to ECG signals tended to report higher discrimination than classical approaches, with the near-term ambulatory ECG anchor study reporting an AUROC 0.948 and the long-term 12-lead ECG anchor study reporting an AUROC 0.820. These comparisons are descriptive and reflect between-study differences in endpoints, horizons, and validation design.14,16 In the anchor evidence, multimodal deep learning (DEEP-RISK) reported an AUROC of 0.84, whereas the radiomics anchor study reported an AUROC of 0.70.13,22 Radiomic analysis of CMR images combined with logistic regression or other traditional classifiers showed modest discrimination in the available studies, although interpretation is limited by single-study evidence and differences in populations and endpoints. Traditional machine-learning models utilizing tabular data or manually crafted features (LASSO, random forest, logistic regression) attained AUROCs between 0.73 and 0.76, showing moderate effectiveness in discrimination. In Ginder (2023), the neural network reported higher discrimination than logistic regression within the same dataset.24
Interpretation and implicationsAcross the included studies, deep learning applied to ECG, particularly ambulatory single-lead recordings, showed the highest reported discrimination for near-term ventricular tachyarrhythmias. Multimodal models showed moderate-to-good discrimination for intermediate-term horizons in the limited available evidence, whereas CMR radiomics-only and classical ML approaches generally reported lower discrimination. These contrasts are indirect and likely reflect differences in endpoints, horizons, and validation design. Multimodal models may offer incremental value for intermediate horizons, but this requires confirmation in independent external cohorts with prespecified endpoints and calibration reporting. Nonetheless, radiomics alone and classical machine-learning methods are constrained, and while ICD/IEGM-based models show promise, they still necessitate external validation. Traditional machine-learning models with AUROCs in the mid-0.70 range may be beneficial in exploratory research or hypothesis generation; nevertheless, they may be insufficient as standalone clinical decision-making tools without stronger external validation and calibration reporting.
Although AUROC was the most consistently reported performance metric, discrimination alone is insufficient for clinical deployment in a low-prevalence, high-impact outcome such as SCD. A model may achieve a high AUROC yet still have limited clinical value if calibration is poor, if the positive predictive value is low at clinically acceptable thresholds, or if the net benefit is inferior to existing decision strategies. Reporting of calibration, threshold-dependent performance, positive and negative predictive values, and decision-curve analysis was sparse and inconsistent across the included studies, limiting assessment of whether these models could support real-world ICD referral, monitoring intensification, or other clinical decisions.
To support interpretation, we separated prespecified anchor estimates (AUROC with 95% CIs within clinically coherent subgroups) from supplementary evidence where uncertainty was not reported or the prediction task/context differed. Anchor estimates provide the most interpretable benchmarks currently available, whereas supplementary findings should be viewed as hypothesis-generating. Future studies should use prespecified endpoints and horizons, include independent external test cohorts, and report calibration alongside discrimination.
Strengths of this review include protocol registration, PRISMA-guided reporting, dual-reviewer screening/extraction, and use of PROBAST+AI to appraise methodological quality and reporting. We also prespecified modality/horizon groupings and avoided pooling across clinically incompatible prediction tasks to reduce false precision.
Endpoint heterogeneity is a central limitation of the current evidence base. The included studies addressed related but non-interchangeable outcomes, including sudden cardiac death, sudden cardiac arrest, sustained VT/VF, appropriate ICD therapy, in-hospital cardiac arrest, and arrhythmic phenotype or triage tasks. These endpoints differ in pathophysiology, baseline prevalence, ascertainment methods, clinical consequences, and therapeutic implications. Therefore, AUROC values should not be compared as if they reflected the same prediction problem. This was the main rationale for avoiding formal pooling and for separating prespecified anchor subgroup estimates from supplementary evidence.
Future researchFuture studies should prioritize: (1) standardized endpoint definitions and prespecified prediction horizons to enable cross-study comparability; (2) independent external validation in diverse cohorts, ideally with multicenter prospective designs; and (3) transparent reporting of uncertainty, calibration, threshold-dependent operating characteristics, handling of repeated measures, and safeguards against data leakage, alongside clear separation of training, tuning, and testing datasets. Before AI-based SCD prediction tools can be considered for routine clinical implementation, future studies should move beyond discrimination reporting alone. Models should undergo independent external validation, calibration assessment, threshold-based evaluation, and preferably decision-curve analysis to determine whether they provide clinical net benefit over existing strategies. Prospective impact studies will also be required to show that model-guided decisions improve patient selection, monitoring intensity, ICD referral, or other management pathways without increasing unnecessary interventions.
LimitationsSeveral limitations warrant consideration. First, only five studies reported AUROC with confidence intervals and were eligible for anchor subgroup reporting; each prespecified subgroup was represented by a single study, preventing pooled estimates and formal heterogeneity assessment. Secondly, outcome criteria and prediction horizons varied from seconds to years and encompassed SCD, sustained ventricular tachyarrhythmias, appropriate ICD therapies, and IHCA, necessitating restriction to clinically coherent subgroups. Third, many reports relied on internal cross-validation, lacked calibration reporting, or did not provide confidence intervals, and such studies were analyzed separately as supplementary evidence. Publication bias could not be assessed, and selective reporting is possible. Model performance may also vary with changes in data acquisition and clinical practice, supporting the need for ongoing external validation. Some models were developed in case–control designs, which can yield optimistic discrimination and do not support estimation of absolute risk or calibration in the target population.
ConclusionPublished AI/ML models for SCD-related prediction tasks report variable performance across modalities and study designs. In the anchor evidence base with AUROC and 95% confidence intervals, deep learning applied to ambulatory ECG shows the highest reported discrimination for near-term ventricular tachyarrhythmias, while 12-lead ECG and multimodal approaches show promising discrimination for longer horizons. However, the evidence remains limited by single-study subgroups, inconsistent external validation, and incomplete reporting of calibration and uncertainty. Larger, methodologically standardized studies with prespecified endpoints and independent external validation are required before AI-based SCD risk tools can be considered for routine clinical use. The limited availability of independent external validation, calibration metrics, and decision-analytic evaluation remains the main barrier to clinical adoption. Until externally validated and calibrated across diverse populations, AI-based SCD prediction tools should remain investigational.
Ethics statementEthics approval was not required as this study was based on previously published data.
FundingThis research received no specific grant from any funding agency in the public, commercial, or not-for-profit sectors.
Conflict of interestThe authors declare no conflicts of interest.
Data availabilityData supporting the findings of this study are derived from previously published studies cited in the manuscript. Extraction tables are available from the corresponding author upon reasonable request.