Leadless pacemaker: A paradigm change
Pacemaker sem elétrodos: uma mudança no paradigma
Visitas
5890
Nicodemus Lopes
Autor para correspondência
nicodemusl@hotmail.com

Corresponding author.
, Diogo Cavaco, Pedro Adragão, Pedro Carmo, Francisco Costa, Francisco Morgado
Centro Hospitalar de Lisboa Ocidental, Hospital de Santa Cruz, Carnaxide, Portugal
Este item recebeu

Under a Creative Commons license
Informação do artigo
Texto Completo
Baixar PDF
Estatísticas
Figuras (3)
Mostrar maisMostrar menos
Texto Completo

We present images of a leadless pacemaker – Micra™ (Medtronic, Inc.) – implanted in the right ventricle through femoral access. We believe it is important for cardiologists to be aware of these radiological images, since the traditional elements of conventional pacing (leads and generators) are absent in these devices.

The patient, an 87-year-old man with permanent atrial fibrillation, normal LV function, and a history of more than 30 years of pacing with leads and generators implanted on both sides of the chest and explanted due to infection, had been fitted with a single-chamber epicardial system with a very high capture threshold.

The leadless pacemaker is delivered through a 27F catheter system, inserted through the femoral vein. Once inside the right ventricle, the catheter system is placed against the septum and the pacemaker is released after obtaining a good position. The pacemaker is secured in the ventricular trabeculae with flexible tines (Figures 1–3). An external programmer is then used to test and program the leadless pacemaker. After adequate parameters are confirmed, the catheter system is removed.

Figure 1.

Advancing the catheter system into the right atrium.

(0,07MB).
Figure 2.

Placing the system against the right ventricular septum and assessing its position with dye.

(0,07MB).
Figure 3.

Final position of the leadless pacemaker.

(0,06MB).

Leadless pacemakers represent a paradigm change in pacing. This patient is among the first group of patients implanted with a Micra system in Portugal (Figures 1–3).

Ethical disclosuresProtection of human and animal subjects

The authors declare that no experiments were performed on humans or animals for this study.

Confidentiality of data

The authors declare that they have followed the protocols of their work center on the publication of patient data.

Right to privacy and informed consent

The authors have obtained the written informed consent of the patients or subjects mentioned in the article. The corresponding author is in possession of this document.

Conflicts of interest

The authors have no conflicts of interest to declare.

Copyright © 2016. Sociedade Portuguesa de Cardiologia
Idiomas
Revista Portuguesa de Cardiologia
Opções de artigo
Ferramentas
en pt

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

Ao assinalar que é «Profissional de Saúde», declara conhecer e aceitar que a responsável pelo tratamento dos dados pessoais dos utilizadores da página de internet da Revista Portuguesa de Cardiologia (RPC), é esta entidade, com sede no Campo Grande, n.º 28, 13.º, 1700-093 Lisboa, com os telefones 217 970 685 e 217 817 630, fax 217 931 095 e com o endereço de correio eletrónico revista@spc.pt. Declaro para todos os fins, que assumo inteira responsabilidade pela veracidade e exatidão da afirmação aqui fornecida.