Informação da revista
Vol. 36. Núm. 11.
Páginas 873-874 (Novembro 2017)
Partilhar
Partilhar
Baixar PDF
Mais opções do artigo
Vol. 36. Núm. 11.
Páginas 873-874 (Novembro 2017)
Image in Cardiology
Open Access
Different patterns of in-stent coverage in drug-eluting stents
Diferentes padrões de cobertura intra-stent em stents farmacológicos
Visitas
3751
Daniele Gemmaa,
Autor para correspondência
daniele.gemma@hotmail.com

Corresponding author.
, Santiago Jimenez Valeroa, Raúl Moreno Gómeza, Francisco Javier Irazusta Córdobab, Pablo Merás Colungab, José Luis López-Sendónb
a Intervencional Cardiology, Hospital Universitario La Paz, Madrid, Spain
b Cardiology, Hospital Universitario La Paz, Madrid, Spain
Este item recebeu

Under a Creative Commons license
Informação do artigo
Texto Completo
Baixar PDF
Estatísticas
Figuras (1)
Texto Completo

A 65-year-old man had undergone percutaneous revascularization of the left anterior descending artery four years earlier, with two non-overlapping stents being implanted in the same procedure: a first-generation drug-eluting stent (DES) in the proximal segment (2.75 mm×16 mm TAXUS Element paclitaxel-eluting stent) and a second-generation DES in the mid segment (2.5 mm×24 mm PROMUS Element everolimus-eluting stent). The patient underwent new coronary angiography for effort angina, which demonstrated diffuse restenosis of the proximal stent, with a 71% obstructive lesion in the mid portion (Figure 1A).

Figure 1.

Initial coronary angiography (A, a) showing diffuse restenosis of the proximal stent and a good late result of the distal stent (arrows); optical coherence tomography (OCT) demonstrating a heterogeneous hypointensive neointima with a bright superficial layer (arrow) and presence of macrophage infiltration and microvessels (asterisk) into the neointima in the first-generation DES (B and b), and a homogeneous hyperintensive neointima in the second-generation DES (C and c); OCT post-stent (D) showing good expansion and apposition of the bioresorbable scaffold.

(0,73MB).

Optical coherence tomography demonstrated two different patterns of in-stent coverage in the two stents: mild proliferation of a homogeneous hyperintense neointima highly suggestive of classic (‘healthy’) neointimal thickening in the distal stent, with minimal luminal area (MLA) of 3.8 mm2 (Figure 1C and c); and a heterogeneous hypointense neointima with low attenuation suggesting an active inflammatory process causing severe restenosis of the TAXUS stent (MLA 2.1 mm2) (Figure 1B and b).

Following predilatation, an Absorb everolimus-eluting bioresorbable scaffold (BRS) (Abbott Vascular, CA) was implanted into the proximal stent, with good results (Figure 1D).

This case reveals a process of restenosis in a first-generation DES and normal neointimal coverage in a second-generation DES implanted in a single patient and artery in the same procedure.

Conflicts of interest

The authors have no conflicts of interest to declare.

Copyright © 2017. Sociedade Portuguesa de Cardiologia
Idiomas
Revista Portuguesa de Cardiologia
Opções de artigo
Ferramentas
en pt

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

Ao assinalar que é «Profissional de Saúde», declara conhecer e aceitar que a responsável pelo tratamento dos dados pessoais dos utilizadores da página de internet da Revista Portuguesa de Cardiologia (RPC), é esta entidade, com sede no Campo Grande, n.º 28, 13.º, 1700-093 Lisboa, com os telefones 217 970 685 e 217 817 630, fax 217 931 095 e com o endereço de correio eletrónico revista@spc.pt. Declaro para todos os fins, que assumo inteira responsabilidade pela veracidade e exatidão da afirmação aqui fornecida.